1477 Cat 6A+ Plenum (CMP) Cable

Part# 1477
Professional-grade Category 6A+ plenum cable for 10-Gigabit Ethernet, AV-over-IP, and high-density PoE++ in air-handling spaces. 23 AWG solid bare copper, 750 MHz, UL Listed CMP.
* Pricing shown is for information only. Contact sales for current pricing.
  • UL Listed
  • ETL Verified
  • CMP Plenum
  • PoE++ Ready
  • RoHS
  • 750 MHz
  • In Stock
  • Made in USA
Best For
  • Enterprise 10G Networks
  • Healthcare / Hospital
  • AV-over-IP (AV/IP)
  • 4PPoE++ Deployments
  • Open-Office Plenum Ceilings
  • Data Centers (short runs)
Not Recommended For
Engineering Buying Guide

Cat6A Augmented Cable: The Engineer – Buying Guide

Cat6A supports 10-Gigabit Ethernet up to 100 meters per TIA-568-C.2-1. It is mandatory for PoE++ (IEEE 802.3bt Type 3/4) installations where heat dissipation and alien crosstalk margin matter.Use this quick reference to match jacket rating, bandwidth, conductor size, and application environment before specifying riser or plenum Cat6A.
Spec Quick Reference
  • Bandwidth
    500 MHz
  • Speed
    10GbE / 10GBASE-T
  • Max run
    100m permanent link
  • AWG
    23 AWG solid bare copper
  • Pairs
    4 pair UTP (F/UTP available)
  • Standard
    ANSI/TIA-568-C.2-1
Recommended Applications
  • High-density PoE++ switch rooms
  • Healthcare/hospital structured cabling
  • Data center horizontal cabling (ToR to workstation)
  • Industrial Ethernet with IEEE 802.3bt Type 3
Selection tip: Choose CMP (Plenum) for open ceiling cable trays and air-handling spaces; CMR (Riser) for vertical runs between floors in non-plenum rated buildings.

Product Detail Snapshot

Cat6A+ 1477 / 1476 Ordering Path
Use Part 1477 when the installation path enters plenum or environmental air spaces. Use Part 1476 for comparable 10GbE Cat6A performance in riser-rated non-plenum building pathways.
Part 1477
Cat6A CMP UTP
Plenum-rated air-handling spaces
  • UL Listed
  • RoHS
  • 310GbE
  • CMP
  • 500MHz
Part 1476
Cat6A CMR UTP
Riser shafts and non-plenum runs
  • UL Listed
  • RoHS 3
  • 10GbE
  • CMR
  • 500 MHz
  • Part 1477
  • Part 1476
Compliance
  • UL Listed
  • RoHS 3
  • TIA-568-C.2-1
  • ANSI/EIA-5
Product Overview
What Is Cat 6A Plenum Cable?
Cat 6A (Augmented Category 6) is the Ethernet cabling standard for 10 Gigabit Ethernet to the full 100-meter channel at 750 MHz. Part 1477 is UTP: four individually twisted pairs of 23 AWG solid bare copper, with a cross-filler spline and CMP plenum jacket rated for open air-handling spaces under NEC 800.154(A).
shield icon
CMP Plenum Jacket

Required by NEC 800.154(A) in any air-handling space — HVAC return ceilings, raised floors, and open plenums. The CMP jacket passes NFPA 262 (UL 910) low-smoke, low-flame-spread testing and may be installed without conduit in air plenums.

wifi icon
Cat 6A vs Cat 6

Cat 6A adds alien crosstalk (ANEXT) control through larger OD (0.295 in), tighter pair geometry, and a cross-filler spline. This enables 10GBase-T to 100m versus Cat 6 which is limited to 55m at 10G. Cat 6A also delivers superior PoE++ thermal performance in dense bundles.

pulse icon
CMP vs CMR

CMP (Plenum) is the highest NEC cable rating and can substitute for CMR, CM, or CMX anywhere in the building. CMR cable may not be used in plenum air-handling spaces. CMP’s NFPA 262-tested jacket limits toxic smoke and flame spread through HVAC systems.

Installer Advantage
Why Installers Choose Syston
thread-spool
EZ-Pull® Jacket

Low-friction jacket compound reduces installation labor by up to 40% on long runs.

box
RhinoPac® Packaging

Crush-resistant pull box survives job-site abuse and dispenses tangle-free every time.

square
UL Listed

UL E-number printed on every foot of jacket — verifiable traceability for AHJ inspections.

Technical Specifications
Part 1477 — Full Spec Sheet
Part Number
1477
Category
Cat 6A+ (Augmented Category 6)
Jacket Rating
CMP — Plenum (NFPA 262 / UL 910)
Conductor
23 AWG Solid Bare Copper
Pairs
4 Pair
Shielding
UTP (Unshielded)
Bandwidth
750 MHz
Max Speed
10 Gigabit Ethernet
Max Distance
100m (328 ft)
Fire Rating
CMP Plenum — NFPA 262
PoE Rating
90W PoE++ (IEEE 802.3bt)
Outer Diameter
0.295 in (7.49 mm)
Insulation
HDPE (High-Density Polyethylene)
Jacket Material
Low-Smoke PVC
Listing
UL Listed, ETL Verified
RoHS
Compliant
Standards
TIA-568.2-D, ISO/IEC 11801, ANSI/TIA-1096-A
Packaging
1,000 ft Pull Box
Country
Made in USA
Cable Construction
23 AWG Cross-Filler Spline Architecture
Cross-Section image
  • 23 AWG Solid Bare Copper · 4 Twisted Pairs
  • Cross-Filler Spline (ANEXT Control)
  • HDPE Pair Insulation
  • Low-Smoke CMP Plenum PVC Jacket
  • OD: 0.295 in · 750 MHz · UL Listed
Standards & Compliance
Certifications and Code Compliance
  • TIA-568.2-D

    TIA-568.2-D

    Full channel compliance for 10GBase-T to 100m at 750 MHz

  • ISO/IEC 11801

    ISO/IEC 11801

    International Class EA channel standard

  • NEC Article 800

    NEC Article 800

    CMP listing satisfies NEC 800.154(A) for air-handling spaces

  • NFPA 262 / UL 910

    NFPA 262 / UL 910

    Plenum fire and smoke test — passes without conduit in open air plenums

  • IEEE 802.3bt

    IEEE 802.3bt

    Supports Type 3 (60W) and Type 4 (90W) PoE++ power delivery

  • UL Listed

    UL Listed

    UL E-number on jacket for AHJ traceability

  • ETL Verified

    ETL Verified

    Third-party performance verification to TIA-568.2-D

  • RoHS Compliant

    RoHS Compliant

    Free of restricted hazardous substances

Typical Applications
Where Part 1477 Is Specified
hotel-icon

Enterprise Campus

10G backbone for corporate campuses and multi-floor open-office environments

camera-icon

Security & Surveillance

10G backbone for high-resolution multi-camera systems and NVR storage

flash iocn

PoE++ Devices

Reliable PoE++ power delivery for next-gen card readers and smart locks

crane-icon

Smart Buildings

Unified cabling backbone for BAS, lighting controls, and HVAC systems

movie-icon

AV-over-IP

Low-latency voice and unified communications infrastructure

monitor-icon

Data Centers

High-density ToR copper links and server connections up to 10GBase-T

house-icon

Residential Networks

Premium whole-home 10G wired backbones and media rooms

hospital-icon

Healthcare

HIPAA-compliant plenum cable for patient areas and clinical networks

graduate-hat

Education

High-capacity classroom, lab, and campus network deployments

industrial-unit(1)

Industrial Networks

Rugged 10G connectivity for manufacturing automation and SCADA

Installation Guide
Cat 6A+ Plenum Installation Best Practices
1

Plan Pathways

Map horizontal runs to keep total channel length under 90m permanent link + 10m patch. Avoid shared pathways with electrical conduit.
2

Pull Cable

Use Syston EZ-Pull® lubricant-free technique. Maintain 25 lbs maximum tension. Never exceed 1-inch bend radius for the 0.295-in OD.
3

Separate from Power

Maintain 6-inch minimum separation from 120V/240V circuits. Use separate cable trays or dividers where parallel runs exceed 10 feet.
4

Terminate

Use Cat 6A-rated jacks and plugs. Limit pair untwist to 0.5 inch maximum at every termination.
5

Test and Verify

Test all channels with a Level IIIe or higher field tester to TIA Cat 6A permanent link limits.
6

Label System

Apply TIA-606-B compliant labels at both ends and patch panel ports before project closeout.
7

INSTALLER TIP

Pre-stage cable drums before pulling. Use cable combs in high-density trays. Test before walls close — never after.
Common Installation Mistakes
alert
Improper grounding
Floating shields on screened cable create ground loops that worsen EMI performance.
alert
Over-untwisting pairs
Untwist no more than 0.5 inch per termination. Excess untwist increases near-end crosstalk.
alert
Mixing categories
One Cat 5e jack limits the entire channel to Cat 5e performance — weakest link governs.
alert
Parallel power routing
AC power runs induce EMI into Cat 6A pairs. Maintain a minimum 6-inch separation.
System Design
Cat 6A+ vs Cat 6e vs Cat 8+ — Decision Guide
FeatureCat 5eCat 6eCat 6A+ (1477)Cat 8+
Max Speed1 Gbps1G / 10G to 55m10 Gbps to 100m40 Gbps to 30m
Bandwidth100 MHz600 MHz750 MHz2000 MHz
PoE++ (90W)LimitedYes (55m) Full 100m Short runs
Plenum (CMP)YesYes Part 1477Yes
AV-over-IPNoLimited Recommended
Data CenterNoNoShort runs Primary
Cost$$$$$$$$$$
FAQ

Cat 6A+ Plenum Cable Questions

Is Part 1477 backwards compatible with Cat 5e and Cat 6 equipment?
Yes. Cat 6A+ is fully backwards compatible with Cat 5e, Cat 6, and Cat 6e equipment. The cable and connectors support all lower-speed protocols. Performance is always governed by the weakest link in the channel — patch cables and jacks must also be Cat 6A-rated for 10GBase-T operation.
Can I use Part 1477 for PoE++ (802.3bt) applications?
Yes. The 23 AWG solid copper conductors and UTP construction of Part 1477 meet the thermal and DC resistance requirements for IEEE 802.3bt Type 3 (60W) and Type 4 (90W) PoE++ at the full 100-meter channel length. Cat 6A is the minimum recommended category for high-density 4PPoE deployments per TIA TSB-184-A.
What is the difference between Part 1477 (CMP) and Part 1476 (CMR)?
Part 1477 has a CMP (plenum) jacket rated by NFPA 262 / UL 910 for installation in air-handling spaces without conduit. Part 1476 has a CMR (riser) jacket for vertical shafts, conduit, and non-plenum horizontal runs. CMP can substitute for CMR anywhere in the building; CMR cannot be used in plenum spaces.
What field tester do I need to certify Cat 6A+ channels?
Use a Level IIIe or higher field tester with Cat 6A permanent link or channel adapters. Common options include the Fluke DSX-600, DSX-8000, and IDEAL Networks LanTEK IV. Test to TIA-568.2-D Cat 6A permanent link limits and retain test reports for AHJ submittal.
How does Cat 6A handle alien crosstalk (ANEXT)?
Cat 6A+ adds alien crosstalk suppression through a larger cable OD (0.295 in), tighter pair geometry, and a cross-filler spline that physically separates the four pairs. When bundles exceed 24 cables, Syston recommends staggered pathway layouts and verified bundle configurations per TIA TSB-155-A.
Is Part 1477 suitable for AV-over-IP (AV/IP) installations?
Yes. Cat 6A+ is the preferred category for SDVoE, NDI, and Dante AV-over-IP protocols that require full-duplex 10GBase-T at 100 meters. The low-latency channel characteristics of Cat 6A are critical for video applications where jitter tolerance is tight.
What is the maximum installation tension for Cat 6A+ cable?
Do not exceed 25 lbs (110 N) pulling tension on Part 1477. Use cable guides at direction changes and avoid tight conduit fill. Crush resistance is 25 lbs/ft. Kinked cable fails ANEXT tests and must be replaced.
Can I use Part 1477 outdoors or in direct burial applications?
No. Part 1477 is rated for indoor air-handling space installation only. For outdoor applications, use a CMX or direct-burial-rated cable. For outdoor runs with conduit, the conduit provides sufficient protection but the cable’s plenum rating does not add UV or moisture resistance.
What connector type does Part 1477 require?
Part 1477 requires Cat 6A-rated RJ45 plugs and keystone jacks. Using Cat 5e or Cat 6 termination hardware limits the channel to the lower category’s performance specification. Verify plug OD compatibility with the 0.295-in cable OD before ordering bulk connectors.
Does Syston provide cut sheets and submittals for Part 1477?
Yes. Contact Syston Technical Support for cut sheets, UL listing verification letters, sample test reports, and CSI MasterFormat spec sections for project submittal packages.
Download Center

Part 1477 Technical Resources

Product Cut Sheet

Product Cut Sheet

Full specifications and ordering information (PDF)
Download
UL Listing Certificate

UL Listing Certificate

UL E-number verification for AHJ submittal
Download
Performance Test Report

Performance Test Report

Third-party TIA-568.2-D channel verification
Download
CSI MasterFormat Spec

CSI MasterFormat Spec

Section 27 11 16 structured cabling spec section
Download
Comparison Sheet

Comparison Sheet

Cat 5e vs Cat 6e vs Cat 6A+ vs Cat 8+
Download
Installation Guide

Installation Guide

Step-by-step Cat 6A+ plenum installation guide
Download
Learning Center

10GbE & Structured Cabling Resources

Ready to Order?

Cat 6A+ Plenum. In Stock. Ships in 48 Hours.

TECHNICAL AUTHORITY

Syston Engineering Team Notes

  • Cat 6A+ cable meets TIA-568-C.2-1 augmented category 6A specifications, supporting 10GBASE-T at 100m with alien crosstalk (ANEXT) margins that exceed the minimum requirement. When specifying for high-density patch panel environments, verify the ANEXT performance of the specific brand — not all Cat 6A products perform equally in bundled channel tests.
  • Plenum-rated Cat 6A+ (CMP) is required in any environmental air-handling space per NEC 800.154. Do not substitute CMR (riser) cable in plenum ceilings even inside conduit unless the NEC authority having jurisdiction approves the conduit as a sealed raceway system — verify locally.
  • For 802.3bt Type 3 and Type 4 PoE++ applications (60W–90W), use 23 AWG or larger conductors and verify that the installed channel meets TIA TSB-184-A thermal guidelines for bundled PoE cable. De-rate ampacity for cables bundled more than 4 deep per NEC 310.15.
  • Cat 6A+ supports alien crosstalk performance through improved pair twist rates and internal separator geometry — field termination technique is critical. Poor termination quality (excessive untwisting at punch-down, improper pairing) is the leading cause of ANEXT failures in field-certified channels. Follow TIA-568 termination procedures exactly.
Syston Engineering Division — Los Angeles, CA — Est. 1992